Best electrical and thermal efficiency in its class. All gas types: natural gas, biogas, mine gas, landfill gas, sewage gas.
| Engine type | Unit | TCG 2020 V12 RW = Optimized for high total efficiency at requested power |
TCG 2020 V12 K K = Optimized for robustness and low CAPEX |
TCG 2020 V12 R = Optimized for high total efficiency |
|||
|---|---|---|---|---|---|---|---|
| 50 Hz | 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| Electrical output | kW | 1000 | 1125 | 1125 | 1200 | 1200 | |
| Thermal output ± 8% | kW | 1056 | 1267 | 1274 | 1189 | 1196 | |
| Electrical efficiency** | % | 43 | 40.7 | 40.4 | 43.7 | 43.4 | |
| Thermal efficiency** | % | 45.4 | 45.8 | 45.8 | 43.3 | 43.2 | |
| Total efficiency | % | 88.4 | 86.6 | 86.2 | 87 | 86.6 | |
| Power to heat ratio *** | – | 0.95 | 0.9 | 0.89 | 1 | 1 | |
| Engine type | Unit | TCG 2020 V16 K K = Optimized for robustness and low CAPEX |
TCG 2020 V16 R = Optimized for high total efficiency |
||
|---|---|---|---|---|---|
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | ||
| Electrical output | kW | 1500 | 1500 | 1560 | 1560 |
| Thermal output ± 8% | kW | 1688 | 1703 | 1576 | 1589 |
| Electrical efficiency** | % | 40.8 | 40.4 | 43.3 | 43 |
| Thermal efficiency** | % | 45.9 | 45.9 | 43.8 | 43.8 |
| Total efficiency | % | 86.7 | 86.3 | 87.1 | 86.8 |
| Power to heat ratio*** | – | 0.89 | 0.89 | 0.99 | 0.98 |
* With 5% O2 and dry exhaust gas
** According to ISO 3046-1
*** The power to heat ratio is calculated by dividing the electrical efficiency by the thermal efficiency. Please remember that this is a theoretical value that may deviate from actually measured values.
The values given in these tables are information purposes only and not binding. The information given in the offer is decisive. Other unit variants with other generators are available.
| Engine type | Unit | TCG 2020 V12 XW = Optimized for operation with biogases at requested power |
TCG 2020 V12 X = Optimized for operation with biogases |
TCG 2020 V16 X = Optimized for operation with biogases |
|||
|---|---|---|---|---|---|---|---|
| 50 Hz | 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| Electrical output | kW | 1000 | 1200 | 1200 | 1560 | 1560 | |
| Thermal output ± 8% | kW | 1055 | 1192 | 1201 | 1566 | 1580 | |
| Electrical efficiency** | % | 42.6 | 43 | 42.7 | 42.7 | 42.9 | |
| Thermal efficiency** | % | 44.1 | 42.7 | 42.7 | 42.9 | 42.8 | |
| Total efficiency | % | 86.7 | 85.7 | 85.4 | 85.6 | 85.1 | |
| Power to heat ratio*** | – | 0.97 | 1 | 1 | 1 | 0.99 | |
* With 5% O2 and dry exhaust gas
** According to ISO 3046-1
*** The power to heat ratio is calculated by dividing the electrical efficiency by the thermal efficiency. Please remember that this is a theoretical value that may deviate from actually measured values.
The values given in these tables are information purposes only and not binding. The information given in the offer is decisive. Other unit variants with other generators are available.
| Engine type | Unit | TCG 2020 V12 RW = Optimized for high total efficiency at requested power |
TCG 2020 V12 K K = Optimized for robustness and low CAPEX |
TCG 2020 V12 R = Optimized for high total efficiency |
TCG 2020 V16 K K = Optimized for robustness and low CAPEX |
TCG 2020 V16 R = Optimized for high total efficiency |
|||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| 50 Hz | 50 Hz | 60 Hz | 50 Hz | 60 Hz | 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||
| Length | mm | 4660 | 4790 | 5970 | 4790 | 5970 | 5430 | 6640 | 5430 | 6640 | |
| Width | mm | 1810 | 1810 | 2210 | 1810 | 1790 | 1810 | 1790 | 1810 | 1790 | |
| Height | mm | 2210 | 2210 | 2210 | 2210 | 2210 | 2210 | 2210 | 2210 | 2210 | |
| Dry weight genset | kg | 11200 | 11200 | 13300 | 14900 | 13300 | 14900 | 13300 | 14900 | ||
| Bore / stroke | mm | 170/195 | 170/195 | 170/195 | 170/195 | 170/195 | 170/195 | 170/195 | 170/195 | ||
| Displacement | dm³ | 53.1 | 53.1 | 53.1 | 53.1 | 53.1 | 70.8 | 70.8 | 70.8 | ||
| Speed | min⁻¹ | 1500 | 1500 | 1800 | 1500 | 1800 | 1500 | 1500 | 1500 | ||
| Mean piston speed | m/s | 9.8 | 9.8 | 9.8 | 9.8 | 9.8 | 9.8 | 9.8 | |||
The values given in these tables are information purposes only and not binding. The information given in the offer is decisive. Other unit variants with other generators are available.
| TCG 2020 V12, V12 K, V16 | First service (check valve clearance)* | Cylinder head inspection | Major overhaul |
|---|---|---|---|
| Natural gas, purified biogas, sewage gas, and landfill gas | 4,000 oh | 32,000 oh** | 64,000 oh |
| Unpurified biogas, sewage gas, and landfill gas | 2,000 oh | 16,000 oh** | 64,000 oh |
| TCG 2020 V12 RW = Optimized for high total efficiency at requested power XW = Optimized for operation with biogases at requested power |
First service (check valve clearance) | Cylinder head inspection | Major overhaul |
|---|---|---|---|
| Natural gas, purified biogas, sewage gas, and landfill gas | 4,000 oh | 40,000 oh** | 80,000 oh |
| Unpurified biogas, sewage gas, and landfill gas | 2,000 oh | 16,000 oh** | 64,000 oh |
* “after commissioning (E10)”
** “at the latest”
The values given in these tables are information purposes only and not binding. The information given in the offer is decisive. Other unit variants with other generators are available.